Technical insulation – materials used for heat insulation of heat networks, pipelines of all types, manufacturing and power (energy) equipment.
“SARMAT” construction holding supplies to the Republic of Belarus virtually the whole range of Rockwool materials used for heat insulation of pipelines, cauldrons, reservoirs and channels. The temperature of the insulated surface should not exceed 1000°Ñ.
“Use of heat-insulating materials in technical insulation”
OUTLINY- FLEXOROCK Cylinders
 |
|
|
They are used for heat insulation of pipelines with heat carrier temperature not more than 250 °Ñ. It is advisable to use them for small diameter pipelines, especially for angle branches and bendings insulation because FLEXOROCK cylinder can be flexibly bent in any place without case destruction and there is also no need to cut it into segments. It facilitates and speeds up the insulation installation especially in irregular shape pipelines and in hard-to-get-at places. |
|
|
Coefficient of heat conductivity λ20 = 0.038 Âò/ì3°C. |
|
|
L-W-60, L-W-80 Mats
 |
|
|
Mineral wool mats with one-sided fiber glass grid revetment. They are used for heat insulation of equipment and pipelines with heat carrier temperature not more than 250 °Ñ (glass cloth covering). It is recommended to use these mats for heat network pipelines, steam condensate return pipes, ÕÂÎ pipelines, mazout lines and other low-temperature pipelines, and also for low-temperature containers and equipment (drain tanks, expanders, separators, heaters and so on). |
|
|
Coefficient of heat conductivity
λ10 (L-W-60) = 0.039 Âò/ì3°C λ10 (L-W-80) = 0.039 Âò/ì3°C
Density: L-W-60 - 58 kg/m3 L-W-80 - 78 kg/m3 |
|
|
ALFAROCK Mats
 |
|
|
They are used for heat insulation of equipment and pipelines with heat carrier temperature not more than 250°Ñ (aluminium foil covering). This material can be used for heat insulation of equipment and pipelines of boiler plants, transfer pumping stations, chemical water cleaning, mazout utilities and other manufacturing equipment and pipelines inside the building. Wool coat and aluminium foil covering allow using mats in places where aesthetics and protection against possible dust pollution are important. |
|
| Insulation temperature |
30 |
70 |
110 |
160 |
190 |
| Heat conductivity, Âò/ì°C |
0,037 |
0,042 |
0,056 |
0,067 |
0,076 |
|
Lamella Mat Mats
 |
|
|
Cross mats for equipment and pipelines with heat carrier temperature not more than 250°Ñ. Lamella Mat Mats have paper covering and Lamella Mat Alu Mats have aluminium foil covering. Mat is fabricated from mineral fiber stripes joined together along the edge by means of paper and foil. This method implies absence of deformation. This material can be recommended for heat insulation of heat network pipelines and other process pipes and manufacturing equipment which should keep the thickness of heat insulation in cross direction under pressure. |
|
|
Coefficient of heat conductivity λ20 = 0.044 Âò/ì3°C.
Density - 36 kg/m3 |
|
|
Wired Mat 70, 80, 105 Mats
 |
|
|
Mats with net of high mechanical strength for insulation of pipelines and armature with heat carrier temperature not more than 1000°Ñ (at vibration – not more than 800°Ñ), wire cloth covering. |
|
|
Coefficient of heat conductivity λ20 = 0.038 Âò/ì3°C.
Density:
WIRED MAT 70 - 70 kg/m3
WIRED MAT 80 - 80 kg/m3
WIRED MAT 105 - 105 kg/m3 |
|
|
Alu Wired Mat 80, 105 Mats
 |
|
|
Mats of high mechanical strength for equipment and pipelines with heat carrier temperature not more than 1000°Ñ (at vibration – not more than 800°Ñ). Alu Wired Mat 80 mats have wire cloth and aluminium foil covering while Alu Wired Mat 150 mats have aluminium foil covering only. They can be recommended for heat insulation of high-temperature manufacturing equipment and process pipelines where mechanical stability, flexibility and easy installation are required. It is also used for heat and sound insulation of steam and gas turbines, gas pipelines and boiler auxiliary equipment (BAE). |
|
|
Coefficient of heat conductivity λ20 = 0.038 Âò/ì3°C.
Density:
ALU WIRED MAT 80 - 80 kg/m3
ALU WIRED MAT 105 - 105 kg/m3 |
|
|
Techrock 60, 80, 100 Plates
 |
|
|
They are recommended for heat insulation of flat surfaces in horizontal and vertical systems and manufacturing equipment (vertical cylindrical reservoirs (V = 63-20000 ì3). |
|
| Insulation temperature 30 70 110 160 190 |
30 |
70 |
110 |
160 |
190 |
| Heat conductivity, Âò/ì°C 0,037 0,042 0,056 0,067 0,085 |
0,037 |
0,042 |
0,056 |
0,067 |
0,085 |
|
Density:
Techrock 60 - 60 kg/m3
Techrock 80 - 80 kg/m3
Techrock 100 - 100 kg/m3 |
|
|
Klimafix Mats
 |
|
|
Self-adhesive mats with one-side aluminium foil covering. They are used for insulation of pipelines, reservoirs and ventilating trunks. |
|
|
Application temperature – up to 250°C. |
|
|
Industrial batts black 60, 80 Plates
 |
|
|
Industrial plates used for heat and sound insulation of ventilating trunk interior surfaces, for sound insulation of attenuators and noise barrier panels, and also for glass facades. They are covered with black fiber glass cloth. |
|
|
Hi-tech Rolled Plates
 |
|
|
Rolled-strip high-temperature plates with special hard upper layer. They are used for heat insulation of steam pipelines with low and high pressure and also for industrial pipelines. |
|
|
Firebatts 110, Alu Firebatts 110 Plates
 |
|
|
FIREBATTS 110 – industrial high-temperature plates used for heat insulation of high-temperature flat surfaces, walls of power-generating boilers, combustion chambers, chimney pipes and fireplaces. |
|
|
ALU FIREBATTS 110 – industrial high-temperature plates with aluminium foil. They are used for heat insulation of high-temperature flat surfaces, walls of power-generating boilers, combustion chambers, chimney pipes and fireplaces. |
|
|
CONLIT 150P, CONLIT 150 A/F Systems
 |
|
|
Mineral wool plates, shaped objects and special CONLIT GLUE adhesive. CONLIT 150P plates are produced without covering and CONLIT 150 A/F plates are produced with aluminium foil covering. CONLIT 150 System is used for fire protection of steel constructions with fire rate up to F3 (three hours) and of ventilating trunks and chimney flues with fire rate up to F2 (two hours). |
|
|
Coefficient of heat conductivity λ30 = 0.035 Âò/ì3°C. Density - 165 kg/m3
|
|
|
|
To get detailed information about heat-insulating materials do not hesitate to ask. |
|
|